Sterisil System

  • No plastic containers for landfill disposal
  • Uses natural, non-toxic disinfectant
  • Class B Ultraviolet Irradiation
  • CDC and ADA compliance means no potential liability
  • Eliminates need for cumbersome and costly purchase of autoclave water
  • No need to add tablets for daily dental water use
  • Fully automated monitoring requiring only a few minutes per year for simple cartridge replacement
  • Sterisil® System for filling bottles (SS-B) or direct water supply plumbed to dental units (SS-D)
  • FDA Cleared, Est. #3005844469
  • EPA Reg. No 83315-2
  • EPA Est. No 83315-CO-001
  • Optional sliding or hinged mounting bracket

The perfect solution to any dental facility!

The Sterisil System has been designed for new construction, extensive remodels or for simple retrofits into an existing office. The Sterisil System is a wall or cabinet mounted point-of-entry water purification system designed to easily connect with the municipal water supply, The Sterisil® System provides water for multiple dental operatories, autoclaves, and drinking water dispensers. The autoclave water is purified to zero ppm total dissolved solids (TDS), with visual and audible alarms that signal the expiration and time for replacement of cartridges. Equipped with a mounting  bracket that is either a sliding or hinged bracket (determined upon when the order is placed).

sterisil system thumb promo badgeThe Sterisil System is engineered to provide “distilled quality” autoclave water and treated dental water (equal to or less than 10 cfu/ml HPC bacteria). This rating is 50 times below the CDC and ADA guideline. This system uses six stages of treatment, including Class B Ultraviolet Irradiation disinfection of protozoan parasites such as Giardia and Cryptosporidium; as well as many microorganisms such as species of Pseudomonas, Streptococcus, Ligionella and Mycobacterium tuberculosis.

Resources: Sterisil System

  • FAQ
  • Part #
  • Videos
  • Docs

  • Will it treat my entire building/office? +

    No, the Sterisil® System is designed to treat dedicated lines to each dental operatory unit, autoclave, or dispensing faucets.
  • What is the life of the filters and UV Light? +

    The life of the Sterisil® System filters and UV light is one year under normal use treating tap water with moderate hardness. If tap water has over 10 grains hardness or high volume of deionized (DI) water is produced for autoclaves, the DI cartridges may need to be replaced more frequently than once a year. The Sterisil® System™ is equipped with automated monitoring to provide notification of this condition.
  • Why has a strange odor suddenly come about? +

    The DI filters have been depleted and require new replacements.
  • How do I change the filters and do I need to turn the main water line off? +

    The main water valve does not need to be shut off but if possible it would be best. The first filter (Stage 1) has been fitted with an automated shut off valve. Unplug the electrical ballast, unscrew the filters, remove and replace with the new filters.
  • How do I change the UV light? +

    With the electrical ballast unplugged, disconnect the plug at the top of the UV light.  Unscrew the inner UV light fitting leaving the outer threaded portion in place (this is the sealed glass sleeve that separates the UV bulb from contact with water).
  • How do I silence the alarm? +

    No need to be alarmed. There are several possibilities for triggering the alarm. Simply contact Sterisil® Technical Assistance for help in determining you specific trigger [1877-755-7873].  If necessary simply unplug the electrical supply cord to temporarily turn off the alarm.
  • Does my incoming water pressure make a difference? +

    Minimum incoming water pressure of 65psi is required.
  • 1

 

Part # Product
  Sterisil® System Microbiological Dental Office/Clinic Water Treatment System
SS-B Sterisil® System Water Treatment System with Electronic Monitors Configured for Filling Bottles, Includes UV and all Cartridges (with BP1)
SS-D Sterisil® System Water Treatment Base System with Electronic Monitors Configured for Direct Water Supply to Dental Units Bottles, Includes UV and all Cartridges (with BP1)
Sterisil® System Replacement Cartridge Packages
SS-AK Stages 1, 2 & 3 + UV Bulb
SS-DI Stage 4, Two Deionization Cartridges
Sterisil® System Filter Packages (2008 models)
PL-FP (1) 6 Operatories or Less. Sterisil® System Filter Replacement Pack
(Stage 1, 2, 3, 4, 5 & UV)
PL-FP (2) 7-15 Operatories. Sterisil® System Filter Replacement Pack
(Stage 1, 2, 3, 4, 5 & UV)
PL-FP (3) 16 + Operatories. Sterisil® System Filter Replacement Pack
(Stage 1, 2, 3, 4, 5 & UV)
PreKit PreKit Sterisil® System PreKit
(Stages 1, 2 & 3)
DI Kit Sterisil® System DI Kit
(3 Stage 4 Filters)
Filter Packages (2005 models)
PLKit 8” 6 or less Operatories, Sterisil® System Filter Replacement Pack
(Stage 1, 2, 3, 4, 6,7& UV)
PLKit 10” 7 to 15  Operatories. Sterisil® System Filter Replacement Pack
(Stage 1, 2, 3, 4, 6,7& UV)
PLKit 12”

16 + Operatories. Sterisil® System Filter Replacement Pack
(Stage 1, 2, 3, 4, 6,7 & UV)

Note: Booster Pump recommended when...

a) Low source water pressure is present/below 65PSi
b) When an elevation change is present between the Sterisil System and Dental Operatory Units Part Number: SS-PB
c) A water pressure regulator is required if one is not present in the building.

    • Step 1: Unpacking +

    • Step 2: Mounting +

    • Step 3: Installation +

    • Step 4: Install Faucet +

    • Flow Control - 4th Generation +

    • Flow Control - 3rd Generation +

    • Pressurization, Monitoring and Maintenance +

    • 1